ROTO <– Change Configuration: 1-Display WiFi Status. 2-Select and Write Config. Item. MPU Mode 1 2 3 4 Toolface Type With Gamma Without Gamma Survey Type Short Long Vert Emph Factor 1.000000 1.500000 2.000000 2.500000 3.000000 Surface System Key Drill Well Resolutions The Fifth Solenoid Enabled Disabled Percentage Steering 0.050000 100% of Time On 90% of Time On 80% of Time On 70% of Time On 60% of Time On 50% of Time On 40% of Time On 30% of Time On 20% of Time On 10% of Time On 0% of Time On Stick Slip Recording Enabled Disabled DI Survey Monit SemiEnabled FullEnabled Lat Shock DF 1 2 3 4 5 6 7 8 9 10 Rec Interval 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 15000 16000 17000 18000 19000 200000 21000 22000 23000 24000 25000 26000 27000 28000 29000 30000 FW Version FW.00.30 FW.00.31 FW.00.32 FW.00.33 FW.00.34 FW.00.35 FW.00.36 FW.00.37 FW.00.38 FW.00.39 FW.00.40 FW.00.41 FW.00.42 FW.00.43 FW.00.44 FW.00.45 FW.00.46 FW.00.47 FW.00.48 FW.00.49 FW.00.50 Turn On RPM 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 Turn Off RPM 2 3 4 5 6 7 8 9 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 Turn On RPM Delay 2 3 4 5 6 7 8 9 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 200 250 300 350 400 450 500 550 600 Turn Off RPM Delay 5 6 7 8 9 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 Downlinking Enabled Disabled SDnlk Listening Period 100 105 110 115 120 125 130 135 140 145 150 155 200 250 300 350 400 SDnlk Timeout Period 60 70 80 90 100 150 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 350 400 450 500 550 600 650 700 710 720 SDnlk Thres. Adjust 10 15 20 25 30 35 40 45 50 55 60 DDnlk Type 1-Disable 2-Enable without Slot 3-Enable with Slot 4-Enable PreAmp Only DDnlk PreAmble Period 1-(10/20/10) 2-(30/55/80) 3-(30/55/30) 4-(15/35/15) DDnlk PreAmble Adjust 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 Svy Report Enabled Disabled Sol. Delay Period Disabled 2 Seconds 4 Seconds 6 Seconds Pressure Monitor Disabled Enabled Target Azi Inc: Click Tool Number: Click Job Location: Click Job Name: Click Board SN: Click Selection will be saved in the database. 3-Display Progress & Result. 4-Reset Result. 5-Reset Config. Selection